VantageNX Tensile Tester (5kN)

The VantageNX-5

Capacity: 5kN, 1125 lbf

Models: 24″ (610 mm), 36″ (915 mm), 48″ (1219 mm)

Description

  • The VantageNX-5 is the ideal solution for those applications that are slightly over the capacity of the Vantage 2kN
  • Models: 24″ (610 mm), 36″ (915 mm), 48″ (1219 mm)
  • What else will you need with the Tensile Tester:
    • Tensile Grips (Pneumatic, Mechanical, Wedge, Vise, Roller) Thwing-Albert Grips
    • Load Cell  
    • Software MAP4
    • Windows 10 compatible with MAP-4 Software.

Additional information

Model Name

5kN Vantage NZ

Industry

Adhesives, Corrugated, Foils/Metals, Food Testing, Medical, Nonwovens, Packaging, Paper, Paperboard, Plastic Film, Pulp, Rigid Plastics, Rubber/Foam, Tissue, Textiles

Testing Property

Tensile, Peel, Compression, COF, Cycling, Tear, Burst, ZDT, Flex/Bend, Stress Relaxation, Thickness, Insertion/Extraction, and more.

List of Standards

ASTM E4, ASTM F88, ASTM D790,  ASTM D791, ASTM D882, ASTM D3330, ISO 5893, ISO 7500-1, ISO 9283, EN 1002/1-4, TAPPI T494, TAPPI T541, TAPPI T811, TAPPI T825, TAPPI T839. (This list shows common standards note that the Vantage can be configured to meet a vast list of standards for ASTM, ISO, TAPPI, DIN, NWSP and others.)

Capacity

5 kN (1125 lbs)

Force Capacity

5 kN (1125 lbs)

Force Measurement

Interchangeable load cells range from 5N (1.1 lbf) to 5kN (1125 lbf)

Force Accuracy

10% to 100% Load Capacity: ±0.25% Measuring Value, Less than 10% Load Capacity: ±0.025% of Load Cell Capacity

Force Resolution

15 bit ADC (0.003% of 1.15 x Load Cell Capacity)

Position Accuracy

±6.4 micron/25 mm (± 0.00025/1.0 inch) or 0.025% of Distance

Position Resolution

1kN Frames: 0.17 μ (6.7 μin), 2kN Frames: 0.05 μ (2.1 μin), 5kN Frames: 0.11 μ (4.2 μin)

Sample Frequency

Selectable: 50, 60, or 250 samples/second

Crosshead Guidance

Precision Ball Screw

Crosshead Speed

1.3 to 1000 mm/min (0.05 to 40 in/min)

Crosshead Speed Accuracy

0.1 to 30 in/min: 1% of Set Speed, <0.1 in/min: 2% of Set Speed, >30 in/min: 2% of Set Speed

Acceleration

0.127 to 127 mm/sec2 (0.005 to 5 in/sec2)

Maximum Power Consumption

1kN & 2kN Frames: 0.6 VA, 5kN Single Column Frames: 1.5 VA, 5kN Dual Column Frames: 1.8 VA

Power Requirements

120-230 VAC ±10%, 50/60 Hz

Operating Environment

Air Temperature – Operating: 10 to 50°C (50 to 122°F)
Relative Humidity – Operating: 10% to 85% (Non-Condensing)

Storage Environment

Air Temperature – Storage: -25 to 70°C (-13 to 158°F)
Relative Humidity – Storage: 5% to 90% (Non-Condensing)

Safety Features

Emergency Stop Button
Upper and Lower Limit Switches with over-travel protection
Electronic Grip Collision Detection
Electronic Load Cell Overload Protection
Mechanical Load Cell Overload Protection:
– 50-250 N: 10 x Load Cell Capacity / 500-2000 N: 5 x Load Cell Capacity / 5-10 kN: 1.5 x Load Cell Capacity

System Control

PC Based

Software

REQUIRES: MAP4 Software